Heat Loss Calculator (U-value / R-value)

Conductive heat loss through a wall, roof or window from area, temperature difference and U-value or R-value (US or SI).

Total assembly R (sum of layers incl. air films). E.g. 3.5 in fiberglass batt ≈ R-11, 6.5 in ≈ R-19 (OpenStax).

Results

Heat loss rate
307.7
Energy per 24 h at this ΔT
2.16
U-value (SI)
0.4368 W/m²·K
R = 2.289 m²·K/W = R-13.00 (US)
Temperature difference
22.22 K (°C)
40.0 °F

Estimate only. This tool is for informational and educational purposes. Results depend on your inputs and simplifying assumptions, and are not a substitute for professional engineering, design or financial advice. Always verify with a qualified professional and applicable codes before purchasing, building or making decisions.

How it’s calculated

Steady-state conduction through a flat assembly is proportional to area and temperature difference, and inversely proportional to its thermal resistance R (for a single layer R = thickness ÷ conductivity). The U-value is 1/R. Assumes steady temperatures, one-dimensional heat flow and no air leakage, solar gain or thermal bridging through studs and framing.

Q = U × A × ΔT = A × ΔT / R 1 ft²·°F·h/Btu = 0.17611 m²·K/W (R-13 US ≈ RSI 2.29)

Example (US units): 100 ft² of wall at R-13 with 70 °F inside and 30 °F outside: Q = 100 × 40 ÷ 13 = 308 BTU/h (90 W).

SI check (OpenStax University Physics, Example 1.10): a foam icebox with A = 0.950 m², 2.50 cm walls and k = 0.035 W/m·°C has R = 0.025 ÷ 0.035 = 0.714 m²·K/W; with ΔT = 35 °C, Q = 0.950 × 35 ÷ 0.714 ≈ 46.6 W.

Add up each surface (walls, windows, roof, floor) and add air-leakage (infiltration) losses for a whole-building estimate; heating equipment should be sized with a full load calculation.

Frequently asked questions

What is the difference between R-value and U-value?

R measures resistance to heat flow (higher is better); U measures conductance (lower is better). For a whole assembly U = 1 / R_total.

Are US and SI R-values the same?

No. US R-values are in ft²·°F·h/Btu; SI (RSI) values are in m²·K/W. Multiply a US R-value by 0.1761 to get RSI.

Can I add R-values of layers?

Yes, for layers in series (e.g. drywall + insulation + sheathing + air films). Parallel paths such as studs need an area-weighted calculation.