How it’s calculated
Spray foam is sold by the board foot: one square foot of surface covered one inch thick (144 in³). So the board feet you need are simply the area in square feet times the thickness in inches. The R-value is the thickness times the R-value per inch of the foam.
| Foam | R per inch (DOE) | Density |
|---|---|---|
| Open-cell | 3.6 | about 0.5 lb/ft³ |
| Closed-cell | 6.1 | about 2 lb/ft³ |
Example: 200 ft² of wall at 3 in thick is 200 × 3 = 600 board feet. With 10% waste that is 660 board feet, or 4 kits of 200 board feet (3.3 rounded up). Open-cell at R-3.6 per inch gives 3 × 3.6 = R-10.8; closed-cell at R-6.1 would give R-18.3.
R-values are typical aged values and vary by product and installation. Kits also state the board feet they cover at a given thickness, and foam must be applied in thin passes within the maker’s limits. Follow the product data sheet and safety instructions, wear the protective gear it requires, and check your local code for thermal-barrier and vapor-control rules.
Frequently asked questions
What is a board foot of spray foam?
One square foot of surface covered with foam one inch thick, or 144 cubic inches. A 200 board foot kit covers 200 ft² at 1 in or 100 ft² at 2 in.
How thick should spray foam be to reach R-13 or R-20?
Divide the R-value you want by the R-value per inch. At R-3.6 per inch (open-cell), R-13 needs about 3.6 in and R-20 about 5.6 in. At R-6.1 per inch (closed-cell), R-13 needs about 2.1 in and R-20 about 3.3 in.
What is the difference between open-cell and closed-cell foam?
Closed-cell foam is denser and rigid, has a higher R-value per inch (about R-6), and resists water. Open-cell foam is lighter, softer and cheaper, with about R-3.6 per inch, and it is not a vapor barrier at typical thicknesses.
How many kits do I need?
Divide the total board feet (with waste) by the board feet printed on the kit and round up. Kit yields are stated for a certain thickness, so use the kit maker’s number.
Embed this calculator
Add this free calculator to your own website. Copy the code below into your page’s HTML:
Need this calculator branded, changed or built around your own prices?See custom business solutions →
Sources
- Which Spray Foam Is Right For You? Appropriate applications for open-cell and closed-cell foam insulation (R-3.6 and R-6.1 per inch, board-foot pricing) — U.S. Department of Energy, Building America
Formulas are taken from the free public references above. Results are provided “as is” for informational and educational purposes only. See our disclaimer.
Added · Last updated · How we check our calculators
Spotted a mistake or missing option? Report a problem· Suggest a calculator