How it’s calculated
The resistance of a uniform wire is proportional to its length and inversely proportional to its cross-section area. The constant of proportionality, the resistivity ρ, depends only on the material. Double the length and the resistance doubles; double the diameter and it falls to a quarter.
Example (OpenStax University Physics Vol. 2, Example 9.5): a 5.00 m copper wire with a diameter of 2.053 mm (AWG 12) has A = 3.31 mm². With ρ = 1.68 × 10⁻⁸ Ω·m, R = 1.68 × 10⁻⁸ × 5.00 ÷ 3.31 × 10⁻⁶ = 0.025 Ω.
Resistivity values are for 20 °C and depend strongly on purity and temperature (copper's resistance rises about 0.39% per °C). Stranded wire, and wire that is heated by the current it carries, will differ. For electrical installations follow the applicable code; this tool is for learning and estimates.
Frequently asked questions
What is the resistance of 12 AWG copper wire?
About 5.1 mΩ per meter (1.55 Ω per 1,000 ft) at 20 °C: 12 AWG has an area of about 3.31 mm², so R/L = 1.68 × 10⁻⁸ ÷ 3.31 × 10⁻⁶.
Why does a thicker wire have less resistance?
More cross-section gives the current more parallel paths. Resistance is inversely proportional to area, so doubling the area halves the resistance.
Copper or aluminum?
Aluminum has about 58% more resistivity than copper (2.65 vs 1.68 × 10⁻⁸ Ω·m), so it needs a larger cross-section for the same resistance, but it is lighter.
Does temperature matter?
Yes. Metals get more resistive as they warm. The values here are at 20 °C; a hot wire has higher resistance.
Embed this calculator
Add this free calculator to your own website. Copy the code below into your page’s HTML:
Need this calculator branded, changed or built around your own prices?See custom business solutions →
Sources
- University Physics Volume 2, §9.3 Resistivity and Resistance (Table 9.1 and Example 9.5) — OpenStax
- American Wire Gauge (AWG) diameter formula D = 0.005 × 92^((36−AWG)/39) inch — University of Illinois Urbana-Champaign, Department of Physics
- ASTM B258: Nominal diameters and cross-sectional areas of AWG sizes (abstract) — ASTM International
Formulas are taken from the free public references above. Results are provided “as is” for informational and educational purposes only. See our disclaimer.
Added · Last updated · How we check our calculators
Spotted a mistake or missing option? Report a problem· Suggest a calculator